Circular ceramic fiber assembly arranged for fit and alignment inspection

01About SYNTHE

Quality control

Material, dimensional, electrical and thermal checks for ceramic fiber products and engineered furnace components.

ISO 9001quality management system
50+testing instruments and systems
1,500+ m²laboratory

02Overview

SYNTHE operates under an ISO 9001 quality management system. Inspection is matched to the product: material form and dimensions for insulation products, machined features for formed parts, and electrical connections and resistance for heated components.

03Manufacturing & quality

Material, dimensional and electrical checks matched to the product.

SYNTHE operates under an ISO 9001 quality management system. Blanket and board orders are checked for the applicable material and dimensional requirements; machined parts add critical-feature checks; heated chambers can add resistance, circuit, lead and terminal checks.

ISO 9001quality management system

Management procedures cover production, inspection and shipment records.

1,500+ m²laboratory

Laboratory space supporting material and product verification.

50+testing instruments and systems

Equipment supporting different material, electrical and thermal checks.

40+patents

Technical development supported by an established patent base.

04Capabilities

Material, dimensional and electrical inspection.

Ceramic fiber board material and dimensional control reference
01

Material controls

Product form determines which grade, density, dimension, mass or surface checks are relevant.

  • Grade and batch context
  • Density or mass where applicable
  • Dimensions and visible condition
Caliper measurement of a drawing-based ceramic fiber component
02

Dimensional controls

Critical-to-fit features are identified from the drawing rather than treating every dimension as equal.

  • Bore and hot-zone geometry
  • Openings, grooves and interfaces
  • Section fit and assembly orientation
Technician using an electrical test instrument on a heating assembly
03

Electrical controls

Heated products can include resistance, wiring, terminal and zone checks when listed in the quotation.

  • Element resistance
  • Circuit and lead arrangement
  • Terminal and sensor interfaces
Inspection planning for drawing revision, dimensions, electrical configuration and packing
04

Inspection records

The agreed inspection documents identify the drawing revision, checked characteristics and packing condition.

  • Drawing and revision identification
  • Product-specific inspection records
  • Packing and shipment protection

05Company information

Typical checks by product type

The quotation, drawing or quality plan lists the checks and records supplied with the order.

ProductCommon checksAdditional checks when specified
Board, blanket and paperGrade, size, thickness, density or mass, appearanceSpecial cut geometry, packing or customer document
Vacuum-formed componentDimensions, density, interfaces and surface conditionMachined tolerances, hardening or thermal evidence
Heated furnace chamberGeometry, element position, resistance, leads and terminalsWiring, voltage or power checks and product-specific thermal records
Large diffusion assemblySections, supports, zones, connections, orientation and packingDrawing-based electrical and inspection records

06How we work

Agree the critical checks before production.

Mark the dimensions, electrical values and packing requirements that affect installation or acceptance. They can then be included in the quotation and inspection record.

Technical brief and drawing review covering product fit, operating conditions, quantity and quotation
  1. 01

    Define critical characteristics

    Identify material, fit, electrical and handling requirements that affect the furnace.

  2. 02

    Choose applicable checks

    Select inspection methods and records that match the product and project risk.

  3. 03

    Inspect during production

    Control the features that become inaccessible after elements, shells or sections are assembled.

  4. 04

    Final inspection

    Confirm agreed characteristics, documentation, marking and packing before shipment.

07Company FAQ

Questions about working with SYNTHE.

01Does SYNTHE operate a quality management system?+

Yes. SYNTHE operates under an ISO 9001 quality management system.

02Can inspection records be supplied with an order?+

Yes. List the required dimensional, visual, electrical or packing record in the inquiry so it can be included in the quotation.

03Are thermal tests performed on every product?+

No. Thermal or firing evidence is applied when relevant to the product, development stage or agreed customer requirement. It is not presented as a universal test for every shipment.

04Can product-specific inspection points be agreed?+

Yes. Critical dimensions, electrical checks, packing requirements and the available inspection records can be listed with the order.

09Project inquiry

List the quality records needed with the quoted product.

List the critical dimensions, material or electrical checks, test method, document format, inspection stage and any packing verification requirement.